---------------------------------------------------------------------- Ovum says ad hoc tools are out-dated. The best practice approach? Fast vulnerability intelligence, threat handling, and setup in one tool. Read the new report on the Secunia VIM: http://secunia.com/products/corporate/vim/ovum_2011_request/ ---------------------------------------------------------------------- TITLE: Schneider Electric Products UnitelWay Device Driver Privilege Escalation Vulnerability SECUNIA ADVISORY ID: SA46534 VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46534/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46534 RELEASE DATE: 2011-10-22 DISCUSS ADVISORY: http://secunia.com/advisories/46534/#comments AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s) http://secunia.com/advisories/46534/ ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS https://ca.secunia.com/?page=viewadvisory&vuln_id=46534 ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/ DESCRIPTION: A vulnerability has been reported in multiple Schneider Electric products, which can be exploited by malicious, local users to gain escalated privileges. The vulnerability is caused due to an error in the UnitelWay device driver when handling certain input and can be exploited to cause a buffer overflow. Successful exploitation may allow execution of arbitrary code. The vulnerability is reported in the following products: * Vijeo Citect version 7.20 and prior. * OPC Factory Server version 3.34. * Telemecanique Driver Pack version 2.6 and prior. * Unity Pro version 6.0 and prior. * Monitor version 7.6 and prior. * PL7 Pro version 4.5 SP5 and prior. SOLUTION: Apply patch. Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ PROVIDED AND/OR DISCOVERED BY: ICS-CERT credits Kuang-Chun Hung, Security Research and Service Institute - Information and Communication Security Technology Center (ICST). ORIGINAL ADVISORY: Schneider Electric: http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page ICS-CERT (ICSA-11-277-01): http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/ ---------------------------------------------------------------------- About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities. Subscribe: http://secunia.com/advisories/secunia_security_advisories/ Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/ Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor. ---------------------------------------------------------------------- Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org ----------------------------------------------------------------------