2. MAINTENANCE SYSTEM DESCRIPTION 2.01 The DMS-100 Family Maintenance System is used to identify faults in the switch, and to take corrective action. 2.02 The Maintenance System uses a telescoping method to access switch components via the hierarchy of system levels. The method requires a user to enter successive commands and parame- ters to locate and treat switch components. The example in Fig- ure 1 on page 10, depicts use of the telescoping method in accessing a component. Subsystems 2.03 The maintenance system, described in 297-1001-106, is com- prised of a quantity of functional areas called subsys- tems. Each subsystem has hardware elements and software resources. It is responsible for a node and all links that are connected to the peripheral side of the node. Nodes and Links 2.04 A node is a hardware unit which can receive or transmit messages. Examples of nodes are: o Network Module (NM) o Peripheral Module (PM) o Input/Output Controller (IOC) A link is a communication medium that is used to pass messages between nodes. It is normally a pair of wires, with appropriate connectors on each end, that interconnects two nodes. For exam- ple: NM junctor a link which connects one NM to another NM speech link a link which connects a NM to a PM 2.05 There are two types of links: speech links carry voice signals and some control signals message links carry only control signals 2.06 When carrying out maintenance activities, directional ref- erences are made to subsystem elements in terms of the Central Control (or the Message Switch(MS)) and the PM (see Fig- ure 2 on page 12). They are: C-Side toward the Central Control (CC) (or the Message Switch ) P-Side toward the PM Page 9 PRACTICE 297-1001-520 RELEASE: 02.03 ÚÄÄÄÄ¿ ³ CI ³ ÀÂÄÄÂÙ ÚÄ>ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ o³o o o o ³ ÚÄÄÄÄÄÄ ÄÄ ÄÄ ÄÄÄÄÄÄÂÄÄÄÄÄÄÁÄÄÄÄÄÄqÚÄÄÄÄÄÄÄ ÄÄ ÄÄ ÄÄÄÄÄÄÄ¿ ³ o³ ³ ÚÄÄÁÄÄ¿ ³ ³MAPCI³ ³ ÀÄÄÂÄÄÙ ³ o o o o o o o o o o o³ Ú ³ ÚÄÄÄÄÄÄÄÄÄÄÂqÄÄÄÄ ÄÄ ÄÄÄÄÄÄÄ ÄÄ ÄÁÄÄÄÄÄÄÄÂÄÄÄÄ ÄÄ ÄÄÄÄÄ¿ ³ ³ ³ ³o ³ ³ ³ ÚÄÁÄÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ³ ³ ³ ³ ³ ³ ³ ³ A´ ÀÄ<Ä´QUIT³ ³MTC³ ³NWM³ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ÀÂÄÂÙ ÀÄÂÄÙ À ³ ³o ³ ÚÄ>ÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³o ÚÄ ÄÅÄ Ä¿ ³ ³o oo Ú ³ ÚÄÄÄÄÄÄÄÂÄÄÄÁÄÄÂqÄÄÄÄÄ ÄÄ ÄÄ ÄÄÄÄÂÄÄ ÄÄ ÄÄÄÂÄÄ ÄÄ ÄÄ ¿ ³ ³ ³ ³ ³o ³ ³ ³ ³ ³ ÚÄÁÄÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ³ ³ ³ ³ ³CC ³ ³CMC³ ³ ³ ³ ³ ³ ³ B´ ÀÄ<Ä´QUIT³ ³(or³ ³(or³ ³PM ³ ³Lns³ ³EXT³ ³ ³ ³ ³CM)³ ³MS)³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ÀÄÂÄÙ ÀÂÄÂÙ ÀÄÂÄÙ ÀÄÂÄÙ ÀÄÂÄÙ À ³ ³o Ú Ä Ù Ä ¿ ÚÄ>ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³o ³ ³ ³ ³o oo Ú ³ ÚÄÄÄÄ ÄÄ ÄÄ ÄÄÄÄÁÄÄÄqÂÄÄÄ ÄÄ ÄÄ ÄÄÄÄÂÄÄÄÄ ÄÄ ÄÄ ÄÄÄÄÄ¿ ³ ³ ³ o³ ³ ³ ³ ³ ÚÄÁÄÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ÚÄÁÄ¿ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄ<Ä´QUIT³ ³TST³ ³BSY³ ³RTS³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ÀÄÂÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ³ o³ C´ oo o³ ³ ÚÄÄÄÄÄqÚÄÄÁÄÄÄÂÄÄÄÄÄ¿ ³ ³ o³ ³ ³ ³ ÚÄÁÄ¿ ÚÄÄÁÄ¿ ÚÄÄÁÄ¿ ÚÄÁÄ¿ ³ ³CMC³ ³CARD³ ³PORT³ ³CLK³ ³ ³No.³ ³No. ³ ³No. ³ ³No.³ À ÀÄÄÄÙ ÀÄÄÄÄÙ ÀÄÄÄÄÙ ÀÄÄÄÙ NOTES: A = Maintenance and Administration systems level B = Maintenance Subsystems level C = Subsystem component level ooo indicates telescoping example Fig. 1 - Telescoping Process. Page 10 PRACTICE 297-1001-520 RELEASE: 02.03 busy inaccessible 2.07 Maintenance action is taken on a subsystem basis. The C-Side of the node, and the C-Side or P-Side of its links, are tested to determine if the subsystem is faulty. 2.08 The configuration of the subsystems is shown in Figure 3 on page 13 and Figure 4 on page 14. The figures illus- trate how each node and link can be related to the C-side and P-side extremities of the system. The C-side of a link inter- faces with the P-side of a node. The P-side of a link interfaces with the C-side of a node. INTERLOCKS 2.09 Software interlocks delay maintenance action that isolates one or more subsystems until confirmation of the action is obtained. A node or link cannot be made manual busy if the action will stop communications to other P-side nodes until a YES reply is received to a confirmation request. If a test fails, the system lists the quantity of circuits in the node or link being tested, or identifies the nodes and links that are affected, and either denies the action or requests confirmation. STATUS 2.10 When a subsystem is accessed for maintenance purposes, the status of its links and node is determined so that appro- priate maintenance action may be taken. The status is changed as a result of maintenance action. 2.11 The status of a link or node is the combination of its state and availability. The state of an element is an indicator of its existence and its readiness to function, while the availability of an element is an indicator of its accessibil- ity for system processes. State 2.12 Typical states of nodes or links are indicated by one of the following codes: - or Uneq UNEQUIPPED. The node name or link exists but the element has not been specified (for example, space exists in store for a NM but no links have been associated with the node). O or OFFL OFFLINE. The node exists but is not available for call processing and does not respond to maintenance functions. This is an interim state before an equipped node is placed in service. The offline state applies to a limited number of links such as DS-1 links. Page 11 PRACTICE 297-1001-520 RELEASE: 02.03 LAST FIRST SUBSYSTEM SUBSYSTEM A SUBSYSTEM B SUBSYSTEM ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ÚÄÄÄÄÄÄÄÄÄÄ¿ Ä Ä ¿ÚÄÄÄÄÄÄÄ¿ <ÄÄC <ÄÄC <ÄÄC ÚÄÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ³ ³Central³ ³ ³ ³ ³ ³ ³ ³Control³ ³ ³ ³ ³ ³ ³ ³ ³<ÄC PÄ>³NODE A³<ÄC PÄ>³NODE B³<ÄC PÄ>³ LAST ³ ³ (or ÃÄÄÄ Ä Ä ÄÄ´ ÃÄÄÄÄÄÄÄÄÄÄÄÄ´ ÃÄÄÄ Ä Ä ÄÄ´ NODE ³ ³Message³ ³ ³ LINK A ³ ³ ³ ³ ³Switch)³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÙ Fig. 2 - Subsystem Structure. M or ManB MANUAL BUSY. The node or link has been removed from service by manual request via a MAP. Only manual requests for further action are allowed. An element is placed in this state to allow maintenance func- tions to be performed on an element. S or SysB SYSTEM BUSY. The node or link has been removed from normal service by system action because a fault has been detected. Both system and manual requests for further action (e.g. test, return-to-service) are allowed.* o or Insv NORMAL. The node or link is fully functional and available for call processing. * Additional states that are exclusive to specific subsystems are in practices describing the MMI for those subsystems. Availability 2.13 The availability of node elements or link elements is indicated by the following codes: o the node or link is available C or C-Side the node or link is inaccessible from the C-Side P or P-Side the link is inaccessible from the P-Side. This indicator is not applicable to node elements. Page 12 PRACTICE 297-1001-520 RELEASE: 02.03 C side P side ÚÄÄÄÄ¿ ÚÄÄÄÄÄ¿ ÚÄÄÄÄÄ¿ ÚÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ³ ³ ³ ³ ³ ÃÄÄÄÄÄ´ ³ ³REMOTE³ ³REMOTE³ ³ CC ÃÄÄ´ CMC ÃÄÄÄ´ NET ÃÄÄÄ¿ ³ PM Ã Ä Ä Ä ´ Ã Ä Ä ´ ³ ³ ³ ³ ÃÄ¿ ³ ÃÄ¿ ³ ³ ³ ³ PM ³ ³ PM ³ ÀÄÄÄÄÙ ÀÄÄÄÄÄÙ ³ ÀÄÄÄÄÄÙ ³ ³ ÀÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ÃÄ´ PM ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ÀÄ´ PM ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³SVC ³ ³ ÀÄÄÄ´ ³ ³ ³CKTS³ ³ ÀÄÄÄÄÙ ³ ³ ³ ÚÄÄÄ¿ ÚÄÄÄÄ¿ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄ´IOCÃÄÄÄ´ DC ÃÄÄÄ´DEV.³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÙ ÀÄÄÄÄÙ ÀÄÄÄÄÙ LEGEND CC - Central Control CMC - Central Message Controller NET - Network PM - Peripheral Module SVC CKT - Service Circuit IOC - Input/Output Controller DC - Device Controller DEV - Device Fig. 3 - System Directional References (for configuration with a Central Control) Page 13 PRACTICE 297-1001-520 RELEASE: 02.03 C side P side ÚÄÄÄÄÄÄ¿ ÚÄÄÄÄÄ¿ ÚÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄ¿ ³ ÃÄÄÄÄÄ´ ÃÄÄÄÄÄ´ ³ ³REMOTE³ ³REMOTE³ ³ MS ÃÄÄÄ¿ ³ NET ÃÄÄÄ¿ ³ PM Ã Ä Ä Ä ´ Ã Ä Ä ´ ³ ³ ÃÄ¿ ³ ³ ÃÄ¿ ³ ³ ³ ³ PM ³ ³ PM ³ ÀÄÄÄÄÄÄÙ ³ ³ ÀÄÄÄÄÄÙ ³ ³ ÀÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ³ ³ ÃÄ´ PM ³ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ³ ÀÄ´ PM ³ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³SVC ³ ³ ³ ÀÄÄÄ´ ³ ³ ³ ³CKTS³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ³ ³ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄ´ CM ³ ³ ³ ³ ³ ÀÄÄÄÄÙ ³ ³ ³ ³ ÚÄÄÄ¿ ÚÄÄÄÄ¿ ÚÄÄÄÄ¿ ³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´IOCÃÄÄÄ´ DC ÃÄÄÄ´DEV.³ ³ ³ ³ ³ ³ ³ ÀÄÄÄÙ ÀÄÄÄÄÙ ÀÄÄÄÄÙ LEGEND CM - Computing Module MS - Message Switch NET - Network PM - Peripheral Module SVC CKT - Service Circuit IOC - Input/Output Controller DC - Device Controller DEV - Device Fig. 4 - System Directional References (for a configuration with a Message Switch Page 14 PRACTICE 297-1001-520 RELEASE: 02.03